newbook.document.writeln(''); newbook.document.close(); newbook.frames[2].location.href = targetFile; } // -->

2    Fibre Channel Hardware, Requirements, and Restrictions

This chapter contains information about the supported Fibre Channel hardware and firmware, and the configuration requirements and restrictions.

2.1    Fibre Channel Hardware Supported for Cluster Storage

Table 2-1 lists the Fibre Channel hardware that is supported for cluster storage by TruCluster Production Server Software Version 1.6 and TruCluster Available Server Software Version 1.6.

Table 2-1:  Fibre Channel Hardware Supported for Cluster Storage

Device Part Number Minimum Firmware Revision  
KGPSA-BC PCI-to-Fibre Channel host adapter 380574-001 V2.20x2  
DS-KGPSA-CA PCI-to-Fibre Channel host adapter 168794-B21 DD302a1.awc  
DS-DSGGA-AA 8-port Fibre Channel switch 380591-B21 1.6b  
DS-DSGGA-AB 16-port Fibre Channel switch 380578-B21 1.6b  
DS-DSGGB-AA 8-port Fibre Channel switch 158222-B21 2.03a  
DS-DSGGB-AB 16-port Fibre Channel switch 158223-B21 2.03a  
DS-SWXHB-07 7-port Fibre Channel Hub 234453-001 NA  
RA8000 with dual-redundant HSG80 array controller 380560-B21 ACS V8.4 or V8.5 [Footnote 1]  
ESA12000 with dual-redundant HSG80 array controller 380580-001 ACS V8.4 or V8.5 [Footnote 1]  

2.2    Fibre Channel Requirements and Restrictions

Table 2-2 lists the supported AlphaServerTM systems with Fibre Channel and the number of KGPSA-BC or KGPSA-CA PCI-to-Fibre Channel adapters that are supported on each system.

Table 2-2:  AlphaServer Systems Supported for Fibre Channel

AlphaServer KGPSA-BC or KGPSA-CA (Fabric) KGPSA-CA (Arbitrated Loop)  
AS800 2 -  
AS1200 4 -  
AS4x00 4 -  
AS8x00 [Footnote 2] [Footnote 3] 32 -  
DS10 [Footnote 4] 2 2  
DS20, DS20E 4 2  
ES40 4 2  
GS60 [Footnote 2] [Footnote 3], GS60E [Footnote 2] [Footnote 3] 32 -  
GS140 [Footnote 2] [Footnote 3] 32 -  

The following requirements and restrictions apply to the use of Fibre Channel with the TruCluster Software Products: