The tables on this page provide a side-by-side comparison
of the hardware configured for the production-level cluster
and the hardware configured for the cluster's associated test
bed. As with any test bed configuration, the test bed environment
does not completely duplicate the production-level cluster
environment. But it is similar enough so that we can understand
the impact of changes before deployment to the production
environment.
|
Servers
|
|
|
Production-Level Cluster
Environment
|
Test Bed Environment
|
|
Models
|
Two AlphaServer
4000 5/533 systems
|
One AlphaServer
1000A 5/333 system and one AlphaServer 1200 5/533 system |
|
CPUs
|
Two AlphaServer 4x00 533MHz Tru64 UNIX
SMP Upgrades (KN305-DB), one for each system
|
Dual CPUs. One
AlphaServer 1200 533 MHz Tru64 UNIX running SMP. One AlphaServer
1000 333 MHz. |
|
Memory
|
1 GB for each system
|
1 GB |
|
I/O Expansion Options
|
Two AlphaServer 4000 PCI I/O Expansion Options
(H7150-AA), one for each system
|
None |
|
Host Bus Adapters
|
Seven PCI-based FWD (Fast, Wide, Differential)
host bus adapters for each system:
- Four KZPBA-CA adapters to connect
each system to its local storage
- Two KZPBA-CA adapters to redundantly
connect each system to shared storage (via UltraSCSI
hub)
- One KZPSA-BB adapter to connect
each system to a shared tape device
|
Four PCI-based
FWD host bus adapters for each system:
- Two KZPBA-CA adapters to connect each system to
shared disk storage
- Two KZPSA-BB adapters to connect each system to
a shared tape device
|
|
Network Adapters
|
-
Two PCI/Fast Ethernet adapters
(DE500-BA), one for each system
-
Four PCI/FDDI adapters (DEFPA-AB),
two for each system
-
Four PCI/Ethernet adapters (DE450),
two for each system
|
-
Two PCI/FDDI adapters (DEFPA-AB),
one for each system
-
Four PCI/Ethernet adapters (DE450),
two for each system
|
|
Memory Channel Adapters
|
Four Memory Channel adapters
(CCMAA-BA), two for each system
|
Two Memory Channel
adapters (CCMAA-BA), one for each system |
|
Power Supplies
|
Six AlphaServer 4XXX power supplies (H7291-AA),
three for each system
|
No additional power supply |
|
Local
Server Storage
|
|
|
Production-Level Cluster
Environment
|
Test Bed Environment
|
|
Storage Shelves
|
- Two UltraSCSI storage shelves (BA36R-RC),
one for each system
- Two UltraSCSI storage shelves (BA356-KH), one for
each system
|
Built-in RA 7000
attached |
|
Storage Shelf Power Supplies
|
Eight StorageWorks
180-Watt Power Supply SSBs (DS-BA35X-HH), two for each
storage shelf |
Five StorageWorks
180-Watt Power Supply SSBs (DS-BA35X-HH) |
|
Cables
|
Four 5-meter UltraSCSI 68HD to VHDCI
cables (BN38C-05) to connect each system to local storage
shelves
|
Same |
|
Disks
|
Ten 4.3-GB 7200Rpm
UltraSCSI disks (DS-RZ1CB-VW), five for each system's
local storage |
The minimum needed
to maintain services |
|
Memory
Channel
|
|
|
Production-Level Cluster
Environment
|
Test Bed Environment
|
|
Memory Channel Hubs
|
Two Memory Channel Hubs (CCMHA-AA)
|
One Memory Channel
Hub (CCMHA-AA) |
|
Memory Channel Line Cards
|
Four linecards (CCMLA), two for
each hub
|
Two linecards
(CCMLA) |
|
Memory Channel Link Cables
|
Four PCI-Memory Channel link cables (BC12N-10),
two for each Memory Channel hub
|
Two PCI-Memory
Channel link cables (BC12N-10) |
|
Shared
Storage
|
|
|
Production-Level Cluster
Environment
|
Test Bed Environment
|
|
Model
|
ESA 10000 High Bandwidth base unit (DS-SWXES-BA)
|
RA 7000 |
|
Cabinet Enclosure Model
|
DataCenter 600 mm enclosure
|
None |
|
Cabinet Power Supplies
|
PDU Redundant for SW600 (DS-SW6XP-AA)
|
No additional
power supply |
|
RAID Controllers
|
Four HSZ70 six-port RAID controllers
(dual-redundant controllers), each with a 64 MB mirrored
write back cache
|
Two HSZ70 six-port
RAID (dual-redundant) controllers, each with a 64-MB mirrored
write back cache |
|
Storage Shelves
|
Eight UltraSCSI storage shelves (BA35R-RC),
four for each set of redundant RAID controllers
|
One UltraSCSI
storage shelf (BA35R-RC) |
|
Storage Shelf Power Supplies
|
Sixteen StorageWorks 180-Watt Power Supply
SSBs (DS-BA35X-HH), two for each storage shelf
|
No additional
power supply |
|
Storage Interconnects
|
Two UltraSCSI hubs (DS-DWZZH-05),
to connect shared buses (two buses from each system) to
the four RAID controllers
|
One UltraSCSI
hub (DS-DWZZH-05) |
|
Cables
|
Four 5-meter UltraSCSI 68HD to VHDCI cables
(BN38C-05), to connect four shared SCSI buses
to the UltraSCSI hub
|
Three 5-meter
UltraSCSI 68HD to VHDCI cables (BN38C-05) |
|
Disks
|
-
Thirty-six 4.3-GB 7200Rpm UltraSCSI
disks (DS-RZ1CB-VW)
-
Eight 9.1-GB 7200Rpm UltraSCSI
disks (DS-RZ1DF-VW)
-
Four 2.1-GB 7200Rpm UltraSCSI disks
(DS-RZ1BB-VW)
|
As required |
|
Tape Drives
|
Two 100/200GB SCSI tape subsystems (TZ885-NT)
|
One 100/200GB
SCSI tape subsystems (TZ885-NT) |
|
SCSI Signal Converters
|
One signal converter (DWZZA-AA)
for the tape drives
|
One signal converter
(DWZZA-AA) |
|